{"id":1957,"date":"2023-06-26T16:31:56","date_gmt":"2023-06-26T07:31:56","guid":{"rendered":"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/?page_id=1957"},"modified":"2025-06-20T14:47:34","modified_gmt":"2025-06-20T05:47:34","slug":"solution-04-01-02","status":"publish","type":"page","link":"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/business\/solution-04\/solution-04-01-02\/","title":{"rendered":"Organic Wastewater"},"content":{"rendered":"\n<div id=\"Main__Inner\">\n\t\t\t\t\t\n\t\t\t\t\t\t<div class=\"Lead__section\">\n\t\t\t\t\t\t\t<div class=\"SiteContent__sectionInner\">\n\t\t\t\t\t\t\t<p class=\"Text\">Treatment of the wastewater containing organic substances mainly by biological methods to remove BOD, COD, N and P and so on.<\/p>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\n\t\t\t\t\t\t\n\t\t\t\t\t\t<div class=\"Block__section\">\n\t\t\t\t\t\t\t<div class=\"BlockSection__Inner\">\n\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t\t<div class=\"GridBox -grid3 -solutionBox\">\n\t\t\t\t\t\t\t\t\t<section class=\"Grid__Item\">\n\t\t\t\t\t\t\t\t\t\t<h3 class=\"heading_Link\"><a href=\"#modal01\" class=\"modalOpen\">Activated Sludge Process with Suspended Carrier<\/a><\/h3>\n\t\t\t\t\t\t\t\t\t\t<div class=\"media_Img\"> <a href=\"#modal01\" class=\"modalOpen\"><img decoding=\"async\" src=\"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/wp-content\/themes\/kke2\/gas\/_img\/img102_03.jpg\" alt=\"\u6d41\u52d5\u62c5\u4f53\u6d3b\u6027\u6c5a\u6ce5\u51e6\u7406\" class=\"img_Liquid--pc waku\"><\/a><\/div>\n\t\t\t\t\t\t\t\t\t\t<div class=\"media_Body js-TileProducts\">\n\t\t\t\t\t\t\t\t\t\t<dl class=\"datalist\">\n\t\t\t\t\t\t\t\t\t\t<dt><span class=\"data_device\">Contaminant<\/span><\/dt>\n\t\t\t\t\t\t\t\t\t\t<dd>Low, medium and high concentrated BOD\/COD and Nitrogen compounds<\/dd>\n\t\t\t\t\t\t\t\t\t\t<dt><span class=\"data_method\">Chemical Symbol\n<\/span><\/dt>\n\t\t\t\t\t\t\t\t\t\t<dd>BOD,COD,T-N,NO<sub>3<\/sub>-N,NH<sub>4<\/sub>-N<\/dd>\n\t\t\t\t\t\t\t\t\t\t<\/dl>\n\t\t\t\t\t\t\t\t\t\t<!-- \/\/media_Body --><\/div>\n\t\t\t\t\t\t\t\t\t<\/section>\n\n\t\t\t\t\t\t\t\t\t<section class=\"Grid__Item\">\n\t\t\t\t\t\t\t\t\t\t<h3 class=\"heading_Link\"><a href=\"#modal02\" class=\"modalOpen\">Membrane Bioreactor<\/a><\/h3>\n\t\t\t\t\t\t\t\t\t\t<div class=\"media_Img\"> <a href=\"#modal02\" class=\"modalOpen\"><img decoding=\"async\" src=\"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/wp-content\/themes\/kke2\/gas\/_img\/img102_02.jpg\" alt=\"\u819c\u5206\u96e2\u6d3b\u6027\u6c5a\u6ce5\u51e6\u7406\" class=\"img_Liquid--pc waku\"><\/a><\/div>\n\t\t\t\t\t\t\t\t\t\t<div class=\"media_Body js-TileProducts\">\n\t\t\t\t\t\t\t\t\t\t<dl class=\"datalist\">\n\t\t\t\t\t\t\t\t\t\t<dt><span class=\"data_device\">Contaminant<\/span><\/dt>\n\t\t\t\t\t\t\t\t\t\t<dd>Low, medium and high concentrated BOD\/COD<\/dd>\n\t\t\t\t\t\t\t\t\t\t<dt><span class=\"data_method\">Chemical Symbol\n<\/span><\/dt>\n\t\t\t\t\t\t\t\t\t\t<dd>BOD, COD<\/dd>\n\t\t\t\t\t\t\t\t\t\t<\/dl>\n\t\t\t\t\t\t\t\t\t\t<!-- \/\/media_Body --><\/div>\n\t\t\t\t\t\t\t\t\t<\/section>\n\n\n\t\t\t\t\t\t\t\t\t<section class=\"Grid__Item\">\n\t\t\t\t\t\t\t\t\t\t<h3 class=\"heading_Link\"><a href=\"#modal03\" class=\"modalOpen\">Denitrification<\/a><\/h3>\n\t\t\t\t\t\t\t\t\t\t<div class=\"media_Img\"> <a href=\"#modal03\" class=\"modalOpen\"><img decoding=\"async\" src=\"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/wp-content\/themes\/kke2\/gas\/_img\/img102.jpg\" alt=\"\u8131\u7a92\u7d20\u51e6\u7406\" class=\"img_Liquid--pc waku\"><\/a><\/div>\n\t\t\t\t\t\t\t\t\t\t<div class=\"media_Body js-TileProducts\">\n\t\t\t\t\t\t\t\t\t\t<dl class=\"datalist\">\n\t\t\t\t\t\t\t\t\t\t<dt><span class=\"data_device\">Contaminant<\/span><\/dt>\n\t\t\t\t\t\t\t\t\t\t<dd>Nitrogen compounds<\/dd>\n\t\t\t\t\t\t\t\t\t\t<dt><span class=\"data_method\">Chemical Symbol\n<\/span><\/dt>\n\t\t\t\t\t\t\t\t\t\t<dd>NO<sub>2<\/sub>-N,NO<sub>3<\/sub>-N,NH<sub>4<\/sub>-N,organic-N<\/dd>\n\t\t\t\t\t\t\t\t\t\t<\/dl>\n\t\t\t\t\t\t\t\t\t\t<!-- \/\/media_Body --><\/div>\n\t\t\t\t\t\t\t\t\t<\/section>\n\n\t\t\t\t\t\t\t\t\t<section class=\"Grid__Item\">\n\t\t\t\t\t\t\t\t\t\t<h3 class=\"heading_Link\"><a href=\"#modal04\" class=\"modalOpen\">[Kenko System]Anaerobic\/Aerobic Treatment<\/a><\/h3>\n\t\t\t\t\t\t\t\t\t\t<div class=\"media_Img\"> <a href=\"#modal04\" class=\"modalOpen\"><img decoding=\"async\" src=\"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/wp-content\/themes\/kke2\/gas\/_img\/img102_04.jpg\" alt=\"\u5acc\u6c17\u597d\u6c17\u6d3b\u6027\u6c5a\u6ce5\u51e6\u7406\u3010\u30b1\u30f3\u30b3\u30fc\u30b7\u30b9\u30c6\u30e0\u3011\" class=\"img_Liquid--pc waku\"><\/a><\/div>\n\t\t\t\t\t\t\t\t\t\t<div class=\"media_Body js-TileProducts\">\n\t\t\t\t\t\t\t\t\t\t<dl class=\"datalist\">\n\t\t\t\t\t\t\t\t\t\t<dt><span class=\"data_device\">Contaminant<\/span><\/dt>\n\t\t\t\t\t\t\t\t\t\t<dd>Low, medium and high concentrated BOD\/COD, N and P<\/dd>\n\t\t\t\t\t\t\t\t\t\t<dt><span class=\"data_method\">Element symbols, etc<\/span><\/dt>\n\t\t\t\t\t\t\t\t\t\t<dd>BOD,COD,T-N,NO<sub>3<\/sub>-N,NH<sub>4<\/sub>-N,NO<sub>2<\/sub>-N,P<\/dd>\n\t\t\t\t\t\t\t\t\t\t<\/dl>\n\t\t\t\t\t\t\t\t\t\t<!-- \/\/media_Body --><\/div>\n\t\t\t\t\t\t\t\t\t<\/section>\n\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t\t\t<section class=\"Grid__Item\">\n\t\t\t\t\t\t\t\t\t\t<h3 class=\"heading_Link\"><a href=\"#modal05\" class=\"modalOpen\">Sequencing Batch Reactor<\/a><\/h3>\n\t\t\t\t\t\t\t\t\t\t<div class=\"media_Img\"> <a href=\"#modal05\" class=\"modalOpen\"><img decoding=\"async\" src=\"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/wp-content\/themes\/kke2\/gas\/_img\/img102_05.jpg\" alt=\"\u5236\u9650\u66dd\u6c17\u51e6\u7406\" class=\"img_Liquid--pc waku\"><\/a><\/div>\n\t\t\t\t\t\t\t\t\t\t<div class=\"media_Body js-TileProducts\">\n\t\t\t\t\t\t\t\t\t\t<dl class=\"datalist\">\n\t\t\t\t\t\t\t\t\t\t<dt><span class=\"data_device\">Contaminant<\/span><\/dt>\n\t\t\t\t\t\t\t\t\t\t<dd>Low, medium and high concentrated BOD\/COD, N and P<\/dd>\n\t\t\t\t\t\t\t\t\t\t<dt><span class=\"data_method\">Chemical Symbol\n<\/span><\/dt>\n\t\t\t\t\t\t\t\t\t\t<dd>BOD, COD, T-N, T-P, P<\/dd>\n\t\t\t\t\t\t\t\t\t\t<\/dl>\n\t\t\t\t\t\t\t\t\t\t<!-- \/\/media_Body --><\/div>\n\t\t\t\t\t\t\t\t\t<\/section>\n\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t\t\t<section class=\"Grid__Item\">\n\t\t\t\t\t\t\t\t\t\t<h3 class=\"heading_Link\"><a href=\"#modal06\" class=\"modalOpen\">UASB System[TROLL](BOD High-Load Anaerobic Treatment)<\/a><\/h3>\n\t\t\t\t\t\t\t\t\t\t<div class=\"media_Img\"> <a href=\"#modal06\" class=\"modalOpen\"><img decoding=\"async\" src=\"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/wp-content\/themes\/kke2\/gas\/_img\/img102_06.jpg\" alt=\"\u5acc\u6c17\u6027\u9ad8\u8ca0\u8377\u51e6\u7406\u3010\u30c8\u30ed\u30eb\u3011\" class=\"img_Liquid--pc waku\"><\/a><\/div>\n\t\t\t\t\t\t\t\t\t\t<div class=\"media_Body js-TileProducts\">\n\t\t\t\t\t\t\t\t\t\t<dl class=\"datalist\">\n\t\t\t\t\t\t\t\t\t\t<dt><span class=\"data_device\">Contaminant<\/span><\/dt>\n\t\t\t\t\t\t\t\t\t\t<dd>Medium and high concentrated BOD\/COD<\/dd>\n\t\t\t\t\t\t\t\t\t\t<dt><span class=\"data_method\">Chemical Symbol\n<\/span><\/dt>\n\t\t\t\t\t\t\t\t\t\t<dd>BOD,COD<\/dd>\n\t\t\t\t\t\t\t\t\t\t<\/dl>\n\t\t\t\t\t\t\t\t\t\t<!-- \/\/media_Body --><\/div>\n\t\t\t\t\t\t\t\t\t<\/section>\n\t\t\t\t\t\t\t\t\t\n\t\t\t\t\t\t\t\t<\/div><!-- \/\/GridBox -->\n\n\t\t\t\t\t\t\t<\/div><!-- \/\/BlockSection__Inner -->\n\t\t\t\t\t\t<\/div><!-- \/\/Block__section -->\n\t\t\t\t\t\t\n\t\t\t\t\t\t\n\t\t\t\t\t\n\t\t\t\t<\/div>\n\n\n\n<!---->\n\n<div class=\"modal\" id=\"modal01\">\n\n<div class=\"overLay modalClose\"><\/div>\n\n<div class=\"inner\">\n\n<p class=\"align--Right\"><a href=\"\" class=\"modalClose\"><img decoding=\"async\" src=\"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/wp-content\/themes\/kke2\/gas\/_img\/btn_close.png\" alt=\"Close\" class=\"rover\"><\/a><\/p>\n\n<h2 class=\"heading_Level2\">Activated Sludge Process with Suspended Carrier<\/h2>   \n\n<div class=\"leftbox\">\n\n<div class=\"media_Img\"><img decoding=\"async\" src=\"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/wp-content\/themes\/kke2\/gas\/_img\/img102_03.jpg\" alt=\"\u6d41\u52d5\u62c5\u4f53\u6d3b\u6027\u6c5a\u6ce5\u51e6\u7406\" class=\"waku\"> \n\n<!-- \/\/media_Img --><\/div>\n\n<\/div>\n\n<div class=\"rightbox\">\n\n<div class=\"media_Body js-TileProducts\">\n\n<dl class=\"datalist\">\n\n<dt><span class=\"data_overview\">Overview<\/span><\/dt>\n\n<dd>Activated sludge process with used of microorganisms clinging to carriers.<\/dd>\n\n<dt><span class=\"data_overview\">Features<\/span><\/dt>\n\n<dd>\uff11\uff09High-load treatment is performed due to high concentration of sludge being retained.<br>\n\n\uff12\uff09High efficiency and space saving.<br>\n\n\uff13\uff09An existing system can be modified to respond to any increase in load demand.<\/dd>\n\n<dt><span class=\"data_overview\">Contaminant<\/span><\/dt>\n\n<dd>Low, medium and high concentrated BOD\/COD and N<\/dd>\n\n<\/dl>\n\n<div class=\"Button -Full -center\"><a href=\"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/wp-content\/uploads\/2023\/09\/k_watertech.pdf\" target=\"_blank\" class=\"Button__inner\" rel=\"noopener\"><span class=\"Button__text\">View Water Technologies catalog<\/span><\/a><\/div>\n\n<!-- \/\/media_Body --><\/div>\n\n<\/div>\n\n<\/div>\n\n<\/div>\n\n\n\n<!---->\n\n<div class=\"modal\" id=\"modal02\">\n\n<div class=\"overLay modalClose\"><\/div>\n\n<div class=\"inner\">\n\n<p class=\"align--Right\"><a href=\"\" class=\"modalClose\"><img decoding=\"async\" src=\"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/wp-content\/themes\/kke2\/gas\/_img\/btn_close.png\" alt=\"Close\" class=\"rover\"><\/a><\/p>\n\n<h2 class=\"heading_Level2\">Membrane Bioreactor<\/h2>   \n\n<div class=\"leftbox\">\n\n<div class=\"media_Img\"><img decoding=\"async\" src=\"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/wp-content\/themes\/kke2\/gas\/_img\/img102_02.jpg\" alt=\"\u819c\u5206\u96e2\u6d3b\u6027\u6c5a\u6ce5\u51e6\u7406\" class=\"waku\"> \n\n<!-- \/\/media_Img --><\/div>\n\n<\/div>\n\n<div class=\"rightbox\">\n\n<div class=\"media_Body js-TileProducts\">\n\n<dl class=\"datalist\">\n\n<dt><span class=\"data_overview\">Overview<\/span><\/dt>\n\n<dd>Activated sludge and treated water are separated by use of membrane instead of a sedimentation tank.<\/dd>\n\n<dt><span class=\"data_overview\">Features<\/span><\/dt>\n\n<dd>\uff11\uff09Space can be minimized since there is no need to install a sedimentation tank.<br>\n\n\uff12\uff09Higher concentration of sludge can be retained.<br>\n\n\uff13\uff09High quality of the treated water can be achieved without filtration.<\/dd>\n\n<dt><span class=\"data_overview\">Contaminant<\/span><\/dt>\n\n<dd>Low, medium, and high concentrated BOD\/COD<\/dd>\n\n<\/dl>\n\n<!--p class=\"btn_waku\"><img decoding=\"async\" src=\"[tp]\/gas\/_img\/icon_arrow_bread.png\" alt=\"\"> <a href=\".pdf\" target=\"_blank\" rel=\"noopener\">See the general water treatment catalogue<\/a><\/p-->\n\n<!-- \/\/media_Body --><\/div>\n\n<\/div>\n\n<\/div>\n\n<\/div>\n\n\n\n<!---->\n\n<div class=\"modal\" id=\"modal03\">\n\n<div class=\"overLay modalClose\"><\/div>\n\n<div class=\"inner\">\n\n<p class=\"align--Right\"><a href=\"\" class=\"modalClose\"><img decoding=\"async\" src=\"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/wp-content\/themes\/kke2\/gas\/_img\/btn_close.png\" alt=\"Close\" class=\"rover\"><\/a><\/p>\n\n<h2 class=\"heading_Level2\">Denitrification<\/h2>   \n\n<div class=\"leftbox\">\n\n<div class=\"media_Img\"><img decoding=\"async\" src=\"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/wp-content\/themes\/kke2\/gas\/_img\/img102.jpg\" alt=\"\u8131\u7a92\u7d20\u51e6\u7406\" class=\"waku\">\n\n<!-- \/\/media_Img --><\/div>\n\n<\/div>\n\n<div class=\"rightbox\">\n\n<div class=\"media_Body js-TileProducts\">\n\n<dl class=\"datalist\">\n\n<dt><span class=\"data_overview\">Overview<\/span><\/dt>\n\n<dd>Denitrification is obtained by microorganisms which reduce nitrate to nitrogen gas.<\/dd>\n\n<dt><span class=\"data_overview\">Features<\/span><\/dt>\n\n<dd>\uff11\uff09The treatment method is appropriately provided in accordance with the specific requirements.<br>\n\n\uff12\uff09Ammonia can be treated by means of ammonia stripping.\n<\/dd>\n\n<dt><span class=\"data_overview\">Contaminant<\/span><\/dt>\n\n<dd>NO<sub>2<\/sub>-N,NO<sub>3<\/sub>-N,NH<sub>4<\/sub>-N,organic-N<\/dd>\n\n<\/dl>\n\n<!--p class=\"btn_waku\"><img decoding=\"async\" src=\"[tp]\/gas\/_img\/icon_arrow_bread.png\" alt=\"\"> <a href=\".pdf\" target=\"_blank\" rel=\"noopener\">See the general water treatment catalogue<\/a><\/p-->\n\n<!-- \/\/media_Body --><\/div>\n\n<\/div>\n\n<\/div>\n\n<\/div>\n\n\n\n<!---->\n\n<div class=\"modal\" id=\"modal04\">\n\n<div class=\"overLay modalClose\"><\/div>\n\n<div class=\"inner\">\n\n<p class=\"align--Right\"><a href=\"\" class=\"modalClose\"><img decoding=\"async\" src=\"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/wp-content\/themes\/kke2\/gas\/_img\/btn_close.png\" alt=\"Close\" class=\"rover\"><\/a><\/p>\n\n<h2 class=\"heading_Level2\">[Kenko System]Anaerobic\/Aerobic Treatment\n<\/h2>   \n\n<div class=\"leftbox\">\n\n<div class=\"media_Img\"><img decoding=\"async\" src=\"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/wp-content\/themes\/kke2\/gas\/_img\/img102_04.jpg\" alt=\"\u5acc\u6c17\u597d\u6c17\u6d3b\u6027\u6c5a\u6ce5\u51e6\u7406\u3010\u30b1\u30f3\u30b3\u30fc\u30b7\u30b9\u30c6\u30e0\u3011\" class=\"waku\"> \n\n<!-- \/\/media_Img --><\/div>\n\n<\/div>\n\n<div class=\"rightbox\">\n\n<div class=\"media_Body js-TileProducts\">\n\n<dl class=\"datalist\">\n\n<dt><span class=\"data_overview\">Overview<\/span><\/dt>\n\n<dd>By combination of anaerobic and aerobic, BOD, N and P are removed.<\/dd>\n\n<dt><span class=\"data_overview\">Features<\/span><\/dt>\n\n<dd>\uff11\uff09Bulking can be prevented, resulting in more stable treatment.\n<br>\n\n\uff12\uff09BOD reduction is 1.5\uff5e2 times more effective than that of a conventional activated sludge method.<br>\n\n\uff13\uff09N and P can be removed at a high rate of 80\uff5e90%.<\/dd>\n\n<dt><span class=\"data_overview\">Contaminant<\/span><\/dt>\n\n<dd>Low, medium, and high concentrated BOD\/COD, N and P<\/dd>\n\n<\/dl>\n\n<!--p class=\"btn_waku\"><img decoding=\"async\" src=\"[tp]\/gas\/_img\/icon_arrow_bread.png\" alt=\"\"> <a href=\".pdf\" target=\"_blank\" rel=\"noopener\">See the general water treatment catalogue<\/a><\/p-->\n\n<!-- \/\/media_Body --><\/div>\n\n<\/div>\n\n<\/div>\n\n<\/div>\n\n\n\n<!---->\n\n<div class=\"modal\" id=\"modal05\">\n\n<div class=\"overLay modalClose\"><\/div>\n\n<div class=\"inner\">\n\n<p class=\"align--Right\"><a href=\"\" class=\"modalClose\"><img decoding=\"async\" src=\"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/wp-content\/themes\/kke2\/gas\/_img\/btn_close.png\" alt=\"Close\" class=\"rover\"><\/a><\/p>\n\n<h2 class=\"heading_Level2\">Sequencing Batch Reactor<\/h2>   \n\n<div class=\"leftbox\">\n\n<div class=\"media_Img\"><img decoding=\"async\" src=\"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/wp-content\/themes\/kke2\/gas\/_img\/img102_05.jpg\" alt=\"\u5236\u9650\u66dd\u6c17\u51e6\u7406\" class=\"waku\">\n\n<!-- \/\/media_Img --><\/div>\n\n<\/div>\n\n<div class=\"rightbox\">\n\n<div class=\"media_Body js-TileProducts\">\n\n<dl class=\"datalist\">\n\n<dt><span class=\"data_overview\">Overview<\/span><\/dt>\n\n<dd>An activated sludge process operated as a batch reactor by a cycle of aeration, settlement and discharge of the treated water.<\/dd>\n\n<dt><span class=\"data_overview\">Features<\/span><\/dt>\n\n<dd>\uff11\uff09Suitable to treat a small amount of wastewater.<br>\n\n\uff12\uff09Bulking can be prevented, resulting in more stable treatment.<br>\n\n\uff13\uff09Stable performance in removal of N and P.<\/dd>\n\n<dt><span class=\"data_overview\">Contaminant<\/span><\/dt>\n\n<dd>Low, medium, and high concentrated BOD\/COD, N and P<\/dd>\n\n<\/dl>\n\n<!--p class=\"btn_waku\"><img decoding=\"async\" src=\"[tp]\/gas\/_img\/icon_arrow_bread.png\" alt=\"\"> <a href=\".pdf\" target=\"_blank\" rel=\"noopener\">See the general water treatment catalogue<\/a><\/p-->\n\n<!-- \/\/media_Body --><\/div>\n\n<\/div>\n\n<\/div>\n\n<\/div>\n\n\n\n<!---->\n\n<div class=\"modal\" id=\"modal06\">\n\n<div class=\"overLay modalClose\"><\/div>\n\n<div class=\"inner\">\n\n<p class=\"align--Right\"><a href=\"\" class=\"modalClose\"><img decoding=\"async\" src=\"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/wp-content\/themes\/kke2\/gas\/_img\/btn_close.png\" alt=\"Close\" class=\"rover\"><\/a><\/p>\n\n<h2 class=\"heading_Level2\">[TROLL]UASB System(BOD High-Load Anaerobic Treatment)<\/h2>   \n\n<div class=\"leftbox\">\n\n<div class=\"media_Img\"><img decoding=\"async\" src=\"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/wp-content\/themes\/kke2\/gas\/_img\/img102_06.jpg\" alt=\"\u5acc\u6c17\u6027\u9ad8\u8ca0\u8377\u51e6\u7406\u3010\u30c8\u30ed\u30eb\u3011\" class=\"waku\">\n\n<!-- \/\/media_Img --><\/div>\n\n<\/div>\n\n<div class=\"rightbox\">\n\n<div class=\"media_Body js-TileProducts\">\n\n<dl class=\"datalist\">\n\n<dt><span class=\"data_overview\">Overview<\/span><\/dt>\n\n<dd>Converting organic substances in wastewater into methane and CO2 by use of anaerobic microorganisms in granular forms.<\/dd>\n\n<dt><span class=\"data_overview\">Features<\/span><\/dt>\n\n<dd>\uff11\uff09Waste generated is much less since methane fermentation is used.<br>\n\n\uff12\uff09Less operational cost since no power is needed for aeration.<br>\n\n\uff13\uff09The methane gas can be collected, converted, and used as an energy source.\n<\/dd>\n\n<dt><span class=\"data_overview\">Contaminant<\/span><\/dt>\n\n<dd>Medium and high concentrated BOD\/COD<\/dd>\n\n<\/dl>\n\n<!--p>\u5acc\u6c17\u6027\u83cc\u3092\u7528\u3044\u3066\u3001\u6392\u6c34\u4e2d\u306e\u6709\u6a5f\u7269\u3092\u30e1\u30bf\u30f3\u30ac\u30b9\u3068\u70ad\u9178\u30ac\u30b9\u306b\u5206\u89e3\u3057\u307e\u3059\u3002\u56de\u53ce\u3057\u305f\u30e1\u30bf\u30f3\u30ac\u30b9\u3092\u30a8\u30cd\u30eb\u30ae\u30fc\u3068\u3057\u3066\u518d\u5229\u7528\u3067\u304d\u307e\u3059\uff01<\/p-->\n\n<div class=\"Button -Full -center\"><a href=\"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/wp-content\/uploads\/2024\/02\/k_troll.pdf\" target=\"_blank\" class=\"Button__inner\" rel=\"noopener\"><span class=\"Button__text\">View Catalogue<\/span><\/a><\/div>\n\n<!-- \/\/media_Body --><\/div>\n\n<\/div>\n\n<\/div>\n\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Treatment of the wastewater containing organic substances mainly by biological methods to remove BOD, COD, N a [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":654,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-solution-level4.php","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-1957","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/wp-json\/wp\/v2\/pages\/1957","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/wp-json\/wp\/v2\/comments?post=1957"}],"version-history":[{"count":30,"href":"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/wp-json\/wp\/v2\/pages\/1957\/revisions"}],"predecessor-version":[{"id":9748,"href":"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/wp-json\/wp\/v2\/pages\/1957\/revisions\/9748"}],"up":[{"embeddable":true,"href":"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/wp-json\/wp\/v2\/pages\/654"}],"wp:attachment":[{"href":"https:\/\/www.kubota-environmentaleng.co.jp\/eng\/wp-json\/wp\/v2\/media?parent=1957"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}